Non Cartridge Pump Seal
  

STEP 1

SPIGOT POSITION MARKING
 
 
  • ENSURE THAT, AXIAL FLOAT OF SHAFT IS NOT MORE THAN 0.08MM & SHAFT RUNOUT ISn WITHIN 0.05MM.
 
  • ASSEMBLE SLEEVE, BACK PLATE & IMPELLER WITH IMPELLER GASKETS, WASHERS & LOCK NUT.
 
  • MARK POSITION OF SPIGOT ON SLEEVE AS SHOWN IN FIGURE USING KNIFE EDGE.
 
  • MEASURE LENTH “X” AS SHOWN IN FIGURE.
 
  Click Here to View Picture

STEP 2


GLAND PLATE /SEAT ASSEMBLY.
 

 
  • ASSEMBLY SEAT (STATIONARY FACE) IN GLAND PLATE USING STATIONARY PKG. – TO BE PRESS FITTED. ENSURE POSITION OF ANTIROTATION PIN IN THE SLOT OF SEAT.
 
  • PLACE GLAND GASKET & MEASURE DISTANCE  “ Y ” BETWEEN GLAND GASKET & SEAT FACE AS SHOWN IN FIGURE.
 
  Click Here to View Picture

STEP 3


ASSEMBLY OF ROTARY HEAD ON SLEEVE.
 

 
  • LUBRICATE THE SLEEVE. DO NOT LUBRICATE SEAL FACE.
 
  • ADJUST THE ROTARY HEAD AT DISTANCE “ D “ SHOWN ABOVE, & LOCK ALL GRUB   SCREWS.
 

          DISTANCE “ D ” = “ X “ + “ Y “ – “OL”  (OPERATING LENTH )

 

          OPERATING LENTH TO BE REFERED FROM SEAL MANUFACTURER

 
  • ASSEMLY THE PUMP WITH GLAND PLATE ASSLY, SLEEVE ASSLY, SLEEVE GASKET, LOCK NUT GASKET, WASHER & IMPELLER.
 
  Click Here to View Picture
STEP 4
COMPLETE ASSEMBLY
 
 
  Click Here to View Picture

Sumika Seals Pvt. Ltd. - Copyrights 2009.

Powered by NETSOL Inc. ---the limit of IT